Installation Instructions
Please read all instructions before installing
DESCRIPTION AND OPERATION
The RS-250 Universal Application Wall Switch Vacancy Sensor is designed to
replace a standard light or fan switch. It is ideal for living and dining rooms, family
rooms, bedrooms, bathrooms and any other indoor area in a residential space
where occupancy sensor-based manual ON/OFF controls are desirable.
Like a standard switch, you press the ON/OFF button to turn the light or fan
(controlled load) ON and OFF. Unlike a standard switch, the RS-250 automatically
turns OFF the controlled load after the coverage area has been vacant for a period
of time (Time Delay). If motion is detected within 30 seconds after it automatically
turns OFF, the RS-250 automatically turns the load back ON.
While the sensor is factory preset as a Vacancy Sensor with manual ON operation,
it can be adjusted to work as an Occupancy Sensor that turns the controlled load
ON automatically upon detection of occupancy in the area.
Lighted Switch
To help you locate the RS-250 in a dark room, the amber LED illuminates the
ON/OFF button while the controlled load is OFF. When the controlled load is ON,
the LED is OFF.
Operating Modes
There are two operating modes to select from during set up:
MODE 1 Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press
the ON/OFF button to turn the load ON. The RS-250 keeps the load ON until no
motion is detected for the selected time delay period (adjustable from 15 seconds
to 30 minutes). There is a 30 second reset delay. If motion is detected during this
time, the sensor turns the load back on automatically. After the reset delay time
has elapsed, the ON/OFF button must be pressed to turn ON the load.
MODE 2 Occupancy sensor (Auto-ON/OFF with manual control and reset
to auto after 5 minutes of vacancy): The load turns ON and OFF automatically
based on occupancy detection. The RS-250 keeps the load ON until no motion is
detected for the selected time delay period. If the load is turned OFF manually,
automatic-ON is re-enabled when no motion is detected for 5 minutes. This
prevents the load from being turned ON after it was deliberately turned OFF.
RS-250
Universal Application Wall Switch
Vacancy Sensor
with Manual ON/OFF
Lens
Lighted Switch
ON/OFF button
SPECIFICATIONS
Voltage ...............................................................120VAC, 60Hz
Load (Single Pole Circuit)
Incandescent or fl uorescent ............................ 0-600 Watts
Fan motor .................................................................. 1/6 hp
Time Delay Adjustment ....................15 seconds to 30 minutes
Light Level Adjustment .......................................10 fc to 150 fc
Environment ..................................Residential Indoor use only
Operating Temperature ............... 32° to 131°F (0° to 55°C)
Humidity ...................................... 95% RH, non-condensing
Tools Needed
Insulated Screwdriver
Wire Strippers
Santa Clara, CA 95050
Call 888.817.0571 for Technical Support
Page view 0
1 2 3 4 5 6 7 8 9 10

Summary of Contents

Page 1 - Installation Instructions

Installation InstructionsPlease read all instructions before installingDESCRIPTION AND OPERATIONThe RS-250 Universal Application Wall Switch Vacancy S

Page 2 - INSTALLATION & WIRING

INFORMACION SOBRE LA GARANTIA DE PRODUCTOWatt Stopper/Legrand garantiza que sus productos están libres de defectos en sus materiales y ensamble por un

Page 3 - PROGRAMMING

Time DelayThe time delay can be selected by the user during set up. It can be adjusted from 15 seconds up to 30 minutes. For additional information on

Page 4 - TROUBLESHOOTING

4. Wire the sensor. Twist the existing wires together with the wire leads on the RS-250 sensor as indicated below. Cap them securely using the wire

Page 5 - WARRANTY INFORMATION

Adjusting the Light LevelThis feature is factory set at maximum, so that even the brightest light will not prevent the sensor from turning the load ON

Page 6 - Instrucciones de Instalación

WARRANTY INFORMATIONWatt Stopper/Legrand warranties its products to be free of defects in materials and workmanship for a period of fi ve (5) years. Th

Page 7 - ADVERTENICA

Instrucciones de InstalaciónPor favor leer todas las instrucciones antes de realizar la instalaciónDESCRIPCION Y OPERACIONEl Sensor de Desocupación de

Page 8 - 1/2"

MODO 2 Sensor de Ocupación (ENCENDIDO/APAGADO automático con control manual y retorno a ENCENDIDO AUTOMATICO después de 5 minutos de desocupación): l

Page 9 - SOLUCION DE PROBLEMAS

Strip Gage1/2"12.7 mmFig. 3: Pelado apropiado del cable4. Conecte el sensor. Tuerza conjuntamente los cables existentes en la caja de conexione

Page 10

• Un patrón de dos parpadeos consecutivos, repetido 3 veces, indicará Modo 2 (Operación como Sensor de Ocupación), ENCENDIDO/APAGADO automático con c

Comments to this Manuals